PES-25: Redundant Cabling

PES 2 — Low Protect

Mechanisms exist to employ redundant power cabling paths that are physically separated to ensure that power continues to flow in the event one of the cables is cut or otherwise damaged.

Renumbered: Formerly PES-07.7 in SCF 2025.4.

Control Question: Does the organization employ redundant power cabling paths that are physically separated to ensure that power continues to flow in the event one of the cables is cut or otherwise damaged?

General (4)
Framework Mapping Values
NIST 800-53 R4 PE-9(1)
NIST 800-53 R5.2 PE-09(01)
NIST 800-82 R3 PE-09(01)
NIST 800-160 Vol2 R1 PE-09(01)
EMEA (1)
Framework Mapping Values
EMEA Germany C5 2026 PS-06.01B.1 PS-06.02AC

Capability Maturity Model

Level 0 — Not Performed

Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.

Level 1 — Performed Informally

Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include: ▪ Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation. ▪ Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices. ▪ Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs). ▪ IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.

Level 2 — Planned & Tracked

Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners. ▪ IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD). ▪ Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards and procedures & guidelines). ▪ Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel. ▪ Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.

Level 3 — Well Defined

Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners. ▪ A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation and proximity badge access). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational capability exists to employ redundant power cabling paths that are physically separated to ensure that power continues to flow in the event one of the cables is cut or otherwise damaged.

Level 4 — Quantitatively Controlled

Utilize SCR-CMM Level 3 criteria definitions: ▪ There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control. ▪ While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define.

Level 5 — Continuously Improving

Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions: ▪ There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control. ▪ Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies. ▪ While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.

Assessment Objectives

  1. PES-25_A01 distance by which redundant power cabling paths are to be physically separated is defined.
  2. PES-25_A02 redundant power cabling paths that are physically separated by organization-defined distance are employed.

Evidence Requirements

E-PES-13 Emergency Power & Utility Protections

Documented evidence of emergency power, emergency shutoff, emergency lighting, voltage controls and redundant cabling.

Physical Security

Technology Recommendations

Micro/Small

  • Note: Typically not required at this size

Small

  • Note: Typically not required at this size; dual power supplies on critical equipment where available

Medium

  • Dual power feeds (A/B) to critical racks
  • Separate circuits for redundant power supplies

Large

  • Physically separated redundant power paths (A/B) in data center
  • Dual-corded critical equipment
  • Power path documentation

Enterprise

  • Enterprise data center power architecture with physically diverse redundant feeds (2N or N+1)
  • DCIM documentation of power paths
  • Regular failover testing