Skip to main content

PES-12.2: Access Control for Output Devices

PES 8 — High Protect

Physical security mechanisms exist to restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.

Control Question: Does the organization restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output?

General (23)
Framework Mapping Values
AICPA TSC 2017:2022 (used for SOC 2) (source) PI1.4
GovRAMP Low+ PE-05
GovRAMP Moderate PE-05
GovRAMP High PE-05
NIST 800-53 R4 PE-5
NIST 800-53 R4 (moderate) PE-5
NIST 800-53 R4 (high) PE-5
NIST 800-53 R5 (source) PE-5
NIST 800-53B R5 (moderate) (source) PE-5
NIST 800-53B R5 (high) (source) PE-5
NIST 800-82 R3 MODERATE OT Overlay PE-5
NIST 800-82 R3 HIGH OT Overlay PE-5
NIST 800-171 R2 (source) 3.10.1
NIST 800-171 R3 (source) 03.10.07.e
NIST 800-171A R3 (source) A.03.10.07.e
PCI DSS 4.0.1 (source) 9.2.2 9.2.3
PCI DSS 4.0.1 SAQ B-IP (source) 9.2.2
PCI DSS 4.0.1 SAQ C (source) 9.2.2
PCI DSS 4.0.1 SAQ D Merchant (source) 9.2.2 9.2.3
PCI DSS 4.0.1 SAQ D Service Provider (source) 9.2.2 9.2.3
SCF CORE Mergers, Acquisitions & Divestitures (MA&D) PES-12.2
SCF CORE ESP Level 2 Critical Infrastructure PES-12.2
SCF CORE ESP Level 3 Advanced Threats PES-12.2
US (19)
EMEA (1)
Framework Mapping Values
EMEA Israel CDMO 1.0 18.7
APAC (1)
Framework Mapping Values
APAC Australia ISM June 2024 ISM-1036
Americas (1)
Framework Mapping Values
Americas Canada ITSP-10-171 03.10.07.E

Capability Maturity Model

Level 0 — Not Performed

There is no evidence of a capability to restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.

Level 1 — Performed Informally

C|P-CMM1 is N/A, since a structured process is required to restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.

Level 2 — Planned & Tracked

Physical & Environmental Security (PES) efforts are requirements-driven and governed at a local/regional level, but are not consistent across the organization. CMM Level 2 control maturity would reasonably expect all, or at least most, the following criteria to exist:

  • Physical access control is decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices.
  • IT/cybersecurity personnel identify cybersecurity and data protection controls that are appropriate to address applicable statutory, regulatory and contractual requirements for physical access control.
  • Human Resources, or a similar function, maintains a current list of personnel with authorized access to organizational facilities and facilitates the implementation of physical access management controls.
  • Physical security controls are primarily administrative in nature (e.g., policies & standards).
  • Physical controls, administrative processes and technologies are primarily designed and implemented for offices, rooms and facilities that focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
  • A facilities maintenance team, or similar function, manages the operation of automated physical and environmental protection controls.
  • Administrative processes, physical controls and technologies restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.
Level 3 — Well Defined

Physical & Environmental Security (PES) efforts are standardized across the organization and centrally managed, where technically feasible, to ensure consistency. CMM Level 3 control maturity would reasonably expect all, or at least most, the following criteria to exist: o Performs the centralized-management of physical security controls across the enterprise. o Maintains a current list of personnel with authorized access to organizational facilities and implements physical access management controls.

  • A physical security team, or similar function:
  • A facilities maintenance team, or similar function, manages the operation of environmental protection controls.
  • Administrative processes exist to authorize physical access to facilities based on the position or role of the individual.
  • Administrative processes and physical controls restrict unescorted access to facilities to personnel with required security clearances, formal access authorizations and validated the need for access.
  • Administrative processes, physical controls and technologies restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.
Level 4 — Quantitatively Controlled

Physical & Environmental Security (PES) efforts are metrics driven and provide sufficient management insight (based on a quantitative understanding of process capabilities) to predict optimal performance, ensure continued operations and identify areas for improvement. In addition to CMM Level 3 criteria, CMM Level 4 control maturity would reasonably expect all, or at least most, the following criteria to exist:

  • Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs).
  • Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs).
  • Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties.
  • Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review).
  • Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes.
  • Both business and technical stakeholders are involved in reviewing and approving proposed changes.
Level 5 — Continuously Improving

See C|P-CMM4. There are no defined C|P-CMM5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to restrict access to printers and other system output devices to prevent unauthorized individuals from obtaining the output.

Assessment Objectives

  1. PES-12.2_A01 output devices that require physical access control to output are defined.
  2. PES-12.2_A02 physical access to output devices is controlled to prevent unauthorized individuals from obtaining access to sensitive / regulated data.
  3. PES-12.2_A03 physical access to output devices is controlled to prevent unauthorized individuals from obtaining access to CUI.

Technology Recommendations

Medium

  • Printer management (print only when at the printer with proximity card or code)

Large

  • Printer management (print only when at the printer with proximity card or code)

Enterprise

  • Printer management (print only when at the printer with proximity card or code)

The Secure Controls Framework (SCF) is maintained by SCF Council. Use of SCF content is subject to the SCF Terms & Conditions.

Manage this control in SCF Connect

Track implementation status, collect evidence, and map controls to your compliance frameworks automatically.